Control wiring and splices · CAUSE ARTICLE

Open R or C conductor

A disconnected or broken supply or return interrupts a complete control-power circuit.

What happens

A disconnected or broken supply or return interrupts a complete control-power circuit.

Typical symptoms

Blank thermostat, missing R-to-C voltage at one end, or an outdoor coil with a signal but no return path.

Checks that distinguish this cause

Compare the correct terminal pair at source and destination. With power isolated and wires separated, test the identified segment end to end and inspect terminals.

What can look similar

A battery thermostat can display normally with missing C. Voltage from Y to ground does not prove the coil has a complete Y-to-C circuit.

Repair direction

Repair the specific broken conductor or terminal, preserving cable identification and strain relief.

Verify the repair

Verify control power and operation at the destination under load.

Equipment-specific limits

This guide addresses conventional R, C, Y, G, O/B and Y2 circuits. Communicating buses require their own service procedure; never apply jumpers to unidentified terminals.